WHI-SK10AXHS2 Automatic Restart Pump Controller 3 Pin Plug 1.5 Bar 240V (711943)

SKU: WHI-SK10AXHS2

Description

WHI-SK10AXHS2 Automatic Restart Pump Controller 3 Pin Plug 1.5 Bar

AUTO RESTART AUTOMATIC PUMP CONTROLLER PLUG AND PLAY with round 3 pin socket and pressure gauge. 240V, 1 ph, 10A max, 1.5kW, 2.0hp, IP65, Ports 1” BSPM. Cut in pressure 1.5 bar. Min pump pressure 300kPa. 12 Month Warranty
Features

The White International WHI-SK10AXHS2 controllers are devices used to control electric 240V pumps of 1.5kW or less.

The controller monitors both the pressure and the flow. It controls the operation of the pump automatically. Because of its design, there is no need for a separate pressure (expansion) tank, nor is there any need to adjust start and stop pressures as per traditional pressure switches.

The unit will protect the pump should the water supply fail (due to blockage in the pipe or tank running dry) and will automatically restart normal operation once water is restored.

Features and Benefits
  • Starts and stops the pump automatically when the tap is open or closed. This means the pump does not need to be turned off manually.
  • Maintains a constant pressure from the pump during operation resulting in a reliable water supply.
  • Automatically stops the pump in the situation of no flow (due to inlet pump blockage) and will automatically resume normal operation once the blockage is removed.
  • Automatically restarts the pump in the event of power failure. This gives the homeowner peace of mind that the unit will continue to operate even if they are away for a long period of time.
  • The controller eliminates pressure fluctuations at flows as low as 1L/min.
  • WHI-SK10AXHS2 comes with an approved 3 pin socket lead.
  • The controller incorporates an inbuilt pressure gauge to enable the homeowner to monitor the system pressure without the need of a separate inline pressure gauge. The pressure gauge can also diagnose nuisance upstream water.
  • Drinking water AS/NZS4020 approved in Australia and New Zealand.
Construction Characteristics
Inlet 1" BSP male
Outlet 1" BSP male
Built in non-return valve
No flow/loss of prime protection
Manual start switch (RESET)
Voltage LED (GREEN power on light)
Pump working LED (ORANGE pump on light)
No flow LED (RED failure light)
1.5 metre lead and 3 pin Australian/New Zealand plug
0.6 metre pump power lead, plug and play
Inbuilt 10 bar pressure gauge


Technical Information
Voltage 220V (-6%) / 240V (+6%)
Maximum Current 16(8) Amps
Maximum kW 1.5kW
Frequency 50Hz
Ingress Protection IP65
Maximum Water Temperature 60 deg C.
Starting Pressure 1.5 bar
Recommended Minimum Pump Pressure Required   3.0 bar
Maximum Working Pressure 10 bar
Minimum Flow 1.0 l/m

Click for SPEC SHEET

WHI-SK10AXHS2 Automatic Restart Pump Controller 3 Pin Plug 1.5 Bar

AUTO RESTART AUTOMATIC PUMP CONTROLLER PLUG AND PLAY with round 3 pin socket and pressure gauge. 240V, 1 ph, 10A max, 1.5kW, 2.0hp, IP65, Ports 1” BSPM. Cut in pressure 1.5 bar. Min pump pressure 300kPa. 12 Month Warranty
Features

The White International WHI-SK10AXHS2 controllers are devices used to control electric 240V pumps of 1.5kW or less.

The controller monitors both the pressure and the flow. It controls the operation of the pump automatically. Because of its design, there is no need for a separate pressure (expansion) tank, nor is there any need to adjust start and stop pressures as per traditional pressure switches.

The unit will protect the pump should the water supply fail (due to blockage in the pipe or tank running dry) and will automatically restart normal operation once water is restored.

Features and Benefits
  • Starts and stops the pump automatically when the tap is open or closed. This means the pump does not need to be turned off manually.
  • Maintains a constant pressure from the pump during operation resulting in a reliable water supply.
  • Automatically stops the pump in the situation of no flow (due to inlet pump blockage) and will automatically resume normal operation once the blockage is removed.
  • Automatically restarts the pump in the event of power failure. This gives the homeowner peace of mind that the unit will continue to operate even if they are away for a long period of time.
  • The controller eliminates pressure fluctuations at flows as low as 1L/min.
  • WHI-SK10AXHS2 comes with an approved 3 pin socket lead.
  • The controller incorporates an inbuilt pressure gauge to enable the homeowner to monitor the system pressure without the need of a separate inline pressure gauge. The pressure gauge can also diagnose nuisance upstream water.
  • Drinking water AS/NZS4020 approved in Australia and New Zealand.
Construction Characteristics
Inlet 1" BSP male
Outlet 1" BSP male
Built in non-return valve
No flow/loss of prime protection
Manual start switch (RESET)
Voltage LED (GREEN power on light)
Pump working LED (ORANGE pump on light)
No flow LED (RED failure light)
1.5 metre lead and 3 pin Australian/New Zealand plug
0.6 metre pump power lead, plug and play
Inbuilt 10 bar pressure gauge


Technical Information
Voltage 220V (-6%) / 240V (+6%)
Maximum Current 16(8) Amps
Maximum kW 1.5kW
Frequency 50Hz
Ingress Protection IP65
Maximum Water Temperature 60 deg C.
Starting Pressure 1.5 bar
Recommended Minimum Pump Pressure Required   3.0 bar
Maximum Working Pressure 10 bar
Minimum Flow 1.0 l/m